Fume hoods are an essential tool when working with materials that are aromatic or volatile, vapors, gases, or fine particles that are easily lifted by airflow. There are numerous types of fume hoods. USF St. Petersburg Fume hoods are scheduled to be tested annually to ensure that the proper airflow range is met. The value of airflow identified each year can be found on the inspection card attached to the fume hood. For requests or questions concerning fume hood operation please contact us.
Types of Fume Hoods
Bypass - This type of hood has a bypass mechanism located above the sash face opening that limits an increase of the face velocity as the sash is lowered at or near the closed position. The face velocity remains unchanged when the sash is fully closed.
Conventional/Constant Air Volume - This is the most commonly used fume hood in our laboratories. The amount of exhausted air remains constant when the sash is in a full-open position. As the sash is lowered, the face velocity increases.
Floor-Mounted - This type of hood is used when a large amount of working space is needed or when a large or tall apparatus is being used. One should never walk into a floor-mounted fume hood while in operation and containing hazardous materials unless proper personal protective equipment is worn.
Perchloric Acid - This type of hood is designed specifically for the use of perchloric acid. Perchloric acid vaporizes when heated above ambient temperatures. This can create explosive perchlorate crystals to form within the ductwork of a conventional fume hood. A perchloric acid hood is constructed with materials such as glass, plastic, or stainless steel that are compatible with perchloric acid and its byproducts. It is equipped with a special water wash-down system that removes the perchlorate crystals from all interior surfaces, including the ducts, fans, and stack. The system should be activated when heating or using large amounts of perchloric acid to minimize chemical exposure hazards.
GUIDELINES
To maintain effectiveness and performance and to minimize exposure,
- All operations should be performed at least 6 inches inside the hood
- Avoid rapid movements, such as opening & closing doors, that can create cross-drafts and disrupt airflow
- Keep sash as low as possible. The glass provides a barrier against a spill, splash, or explosion.
- Chemicals and equipment should not be stored permanently inside the hood
- The hood sash or panels must not be removed from the hood or altered.
- Close sash when the hood is not in use
- Check the airflow monitor periodically. If the monitor is alarming, do not use the fume hood. Contact EH&S/Facilities Management (see below).
- Certain chemicals used in large quantities such as perchloric acid, hydrochloric acid, and hydrofluoric acid should not be used in a chemical fume hood that is not approved for their use.
- Radioactive materials may only be used in chemical fume hoods certified by the Radiation Safety Office.
Fume hoods are tested annually (and after repairs) by Environmental Health & Safety to ensure they are functioning properly.
REPAIRS
Never assume your hood is functioning properly. Always check your hood prior to use. Fume hood exhaust fans may shut down due to an unexpected power failure, equipment malfunction, or other unforeseen events. The following steps should be taken to prevent exposure hazards if your hood is not functioning properly:
- Discontinue all operations that may produce hazardous vapors, gases, or dust.
- Securely cap/cover all open chemical containers in the fume hood
- Close fume hood sashes.
- Contact Environmental Health & Safety at 813-974-4036, and/or your campus Facilities
Management Contact.
- All work requests (paying/non-paying) must be submitted through FAMIS. Access to FAMIS is only available through the MyUSF portal > Business Systems tab > Work Orders (FAMIS)
- Campus FM Websites and Contacts:
Tampa Campus: (813) 974-2845 or FM-ServiceCenter@usf.edu
St. Petersburg Campus: (727) 873-4135
Sarasota-Manatee Campus: (941) 359-4519
Do not use the fume hood until it is fully operational
If hazardous vapors, gases, or dust have entered the room, leave the area immediately, and contact Environmental Health & Safety and/or the University Police.